The Load Insulator® is a
self-testing safety device that protects ground personnel,
in contact with the load, from injury or death in the event
of a crane making contact with overhead energised power
lines.
- There are four different lifting capacities.
- Remember you only need the lifting capacity of the
item lifted.
- For permanently mounted installations the unit should
match the cranes lifting capacity.
- Any size, configuration and voltage can be produced
to special order.
- These units can be rented on a weekly basis, subject
to availability. On returning the unit the onboard
diagnostics will be downloaded and the information can
be made available as part of your safety management
program.
|
| MECHANICAL PERFORMANCE |
|
| Safe Working Load, S.W.L |
10t , 25t , 55t ,120t (tonnes) |
| Proof Test Load, P.T.L |
20t, 50t , 110t , 180t (tonnes) |
| Ultimate Load |
500% of Safe Working Load |
| Duty rating |
ISO M5 duty rating |
| ELECTRICAL PERFORMANCE |
|
| Class |
2 |
| Rated Operating Voltage R.O |
25kV rms |
| Rated Test Voltage R.T.V |
32 kV rms |
| Rated Leakage Current R.L.C |
Less than 2mA at 25kV |
| Operating Temperature |
-40°C to +60°C |
| Lightning Strike |
Not lightning proof |
| Warning Device |
Via Onboard Diagnostics |
| MODEL |
Pin diameter |
Hole to Hole |
Weight |
| 10tv1 |
1 ½" |
24" |
106 lb |
| 25tv1 |
2" |
28" |
211 lb |
| 55tv1 |
3" |
34" |
471 lb |
| 120tv1 |
4" |
45" |
1232 lb |
|
|
 |
|
|
|